7.0

Which vSAN Maintenance Mode option was used on a host?

Duncan Epping · Jun 7, 2021 ·

Last week there was a question on VMTN around maintenance mode, this customer wanted to find out which vSAN Maintenance Mode option was used while the host was placed in maintenance mode. The person who placed the host into maintenance wasn’t around, and I guess the customer wanted to know if data was moved from the host or not. They looked at the events and tasks, but unfortunately it wasn’t obvious from that vCenter section, next up were the logs. I also looked at the logs, and you would expect this info to be stored in hostd.log, but it wasn’t, so where is it? Well it actually is a configuration item, and you can dig it up here:

Pre ESXi 7.0 the info is stored in the “esx.conf” file, just grep for “hostDecommission”. Let me show you:

$ grep "/vsan/hostDecommission" /etc/vmware/esx.conf
/vsan/hostDecommissionVersion = "10"
/vsan/hostDecommissionState = "decom-state-decommissioned"
/vsan/hostDecommissionMode = "decom-mode-ensure-object-accessibility"

If the ESX is at 7.0 or later, just run the below config store command:

$ configstorecli config current get -c vsan -g system -k host_state
{
   "decom_mode": "ENSUREOBJECT_ACCESSIBILITY",
   "decom_state": "DECOMMISSIONED",
   "decom_version": 0
}

I hope that helps others who have a similar question!

HCI Mesh error: Failed to run the remote datastore mount pre-checks

Duncan Epping · Apr 21, 2021 ·

I had two comments on my HCI Mesh compute only blogpost where both were reporting the same error when trying to mount a remote datastore. The error that popped up was the following:

Failed to run the remote datastore mount pre-checks.

I tried to reproduce it in my lab, as both had upgraded from 7.0 to U2 I did the same, that didn’t result in the same error though. The error doesn’t provide any details around why the pre-check fails, as shown below in the screenshot. After some digging I found out that the solution is simple though, you need to make sure IPv6 is enabled on your hosts. Yes, even when you are not using IPv6, it still needs to be enabled to pass the pre-checks. Thanks, Jiří and Reza for raising the issue!

HCI Mesh error: Failed to run the remote datastore mount pre-checks

Does vSAN Enhanced Durability work when you have a limited number of hosts?

Duncan Epping · Apr 19, 2021 ·

Last week I had a question about how vSAN Enhanced Durability works when you have a limited number of hosts. In this case, the customer had a 3+3+1 stretched cluster configuration, and they wondered what would happen when they would place a host into maintenance mode. Although I was pretty sure I knew what would happen, I figured I would test it in the lab anyway. Let’s start with a high-level diagram of what the environment looks like. Note I use a single VM as an example, just to keep the scenario easy to follow.

In the diagram, we see a virtual disk that is configured to be stretched across locations, and protected by RAID-1 within each location. As a result, you will have two RAID-1 trees each with two components and a witness, and of course, you would have a witness component in the witness location. Now the question is, what happens when you place esxi-host-1 into maintenance mode? In this scenario, vSAN Enhanced Durability will want to create a “durability component”. This durability component is used to commit all new write IO to. This will allow vSAN to resync fast after maintenance mode, and enhances durability as we would still have 2 copies of the (new) data.

However, in the scenario above we only have 3 hosts per location. The question then is, where is this delta component created then? As normally with maintenance mode you would need a 4th host to move data to. Well, it is simple, in this case, what vSAN does is it creates a “durability component” on the host where the witness resides, within the location of course. Let me show you in a diagram, as that makes it clear instantly.

By adding the Durability component next to the witness on esxi-host-3, vSAN enhances durability even in this stretched cluster situation, as it provides a local additional copy of new writes. Now, of course I tested this in my lab. So for those who prefer to see a demo, check out the youtube video below.

Using HCI Mesh with a stand-alone vSphere host?

Duncan Epping · Apr 13, 2021 ·

Last week at the French VMUG we received a great question. The question was whether you can use HCI Mesh (datastore sharing) with a stand-alone vSphere Host. The answer is simple, no you cannot. VMware does not support enabling vSAN, and HCI Mesh, on a single stand-alone host. However, if you still want to mount a vSAN Datastore from a single vSphere host, there is a way around this limitation.

First, let’s list the requirements:

  1. The host needs to be managed by the same vCenter Server as the vSAN Cluster
  2. The host needs to be under the same virtual datacenter as the vSAN Cluster
  3. Low latency, high bandwidth connection between the host and the vSAN Cluster

If you meet these requirements, then what you can do to mount the vSAN Datastore to a single host is the following:

  1. Create a cluster without any services enabled
  2. Add the stand-alone host to the cluster
  3. Enable vSAN, select “vSAN HCI Mesh Compute Cluster”
  4. Mount the datastore

Note, when you create a cluster and add a host, vCenter/EAM will try to provision the vCLS VM. Of course this VM is not really needed as HA and DRS are not useful with a single host cluster. So what you can do is enable “retreat mode”. For those who don’t know how to do this, or those who want to know more about vCLS, read this article.

As I had to test the above in my lab, I also created a short video demonstrating the workflow, watch it below.

Can I vMotion a VM while IO Insight is tracing it?

Duncan Epping · Mar 4, 2021 ·

Today during the Polish VMUG we had a great question, basically, the question was if you can vMotion a VM while vSAN IO Insight is tracing it. I did not know the answer as I had never tried it, so I had to test and validate it in the lab. While testing it became obvious that IO Insight and vMotion are not a supported combination today. Or better said, when you vMotion a VM which has IO Insight enabled and the VM is being traced, then the tracing will stop and you will not be able to inspect the results. When you click on view results you will see the error suggesting that the “monitored VMs might be deleted” as shown below.

For now, if you are tracing a VM for an extended period of time, make sure to override the DRS automation level for that VM so that DRS does not interfere with the tracing. (You can do this on a per VM basis.) I would also recommend informing other administrators to not manually migrate the VM temporarily to avoid the situation where the trace is stopped.  You may wonder why this is the case, well it is pretty simple, tracing happens on a host level. We start a user world on the host where the VM is running to trace the IO. If you move the VM, the user world doesn’t know what has happened to the VM unfortunately. For now, who knows if this is something that may change over time… Either way, I would always recommend not migrating VMs while tracing, as that also impacts the data.

Hope that helps, and thank Tomasz for the great question!

  • « Go to Previous Page
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Interim pages omitted …
  • Page 8
  • Go to Next Page »

Primary Sidebar

About the Author

Duncan Epping is a Chief Technologist and Distinguished Engineering Architect at Broadcom. Besides writing on Yellow-Bricks, Duncan is the co-author of the vSAN Deep Dive and the vSphere Clustering Deep Dive book series. Duncan is also the host of the Unexplored Territory Podcast.

Follow Us

  • X
  • Spotify
  • RSS Feed
  • LinkedIn

Recommended Book(s)

Advertisements




Copyright Yellow-Bricks.com © 2025 · Log in